Thursday, January 23, 2014

// // Leave a Comment

What are the Ponding Considerations In Buildings?

Those flat roof which face a problem of water accumulation require stability analysis under ponding conditions. For checking the stability we need to see the following equations, if both of these are fulfilled
Cp+0.9Cs<= 0.25
Id>=25S4/106
Where
p= 32 Ls L4p/107Ip
Cs=32Ls4/107Is
Lp= Length of primarymember or girder in ft (m)
Ls= Length of secondary member or purlin ft (m)
S= Spacing of secondary members ft (m)
Ip= Moment of inertia of primary member in in4 mm4
Is= Moment of inertia of secondary member in in4 mm4
d= Moment of inertia of steel deck supported on secondary members, in4/ft (mm4/m)
It should be noted that Is should be decreased by 15% for trusses and other open-web members. Also the value of the total bending stress due to ponding , dead loads and live loads should not exceed 0.80Fy(the minimum specified yield stress for the steel)

0 comments:

Post a Comment